Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 10: 1453-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27536058

RESUMO

Ultrasound biomicroscopy is a non-invasive imaging technique, which allows high-resolution evaluation of the anatomical features of the anterior segment of the eye regardless of optical media transparency. This technique provides diagnostically significant information in vivo for the cornea, anterior chamber, chamber angle, iris, posterior chamber, zonules, ciliary body, and lens, and is of great value in assessment of the mechanisms of glaucoma onset. The purpose of this paper is to review the use of ultrasound biomicroscopy in the diagnosis and management of rare diseases of the anterior segment such as mesodermal dysgenesis of the neural crest, iridocorneal endothelial syndrome, phakomatoses, and metabolic disorders.

2.
Acta Ophthalmol ; 90(4): e288-94, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22268459

RESUMO

PURPOSE: To assess subfoveal choroidal blood flow (ChBF) in patients with early manifest glaucoma (EMG) and to compare blood flow with functional measures of central retinal integrity, standard automated perimetry (SAP) and pattern electroretinogram (PERG). METHODS: Subfoveal ChBF was determined by confocal, real-time laser Doppler flowmetry in 24 patients with EMG [>-6 dB mean deviation (MD), age range: 29-77 years, visual acuity: 20/25-20/20] and 23 age-matched control subjects. All patients had a therapeutically (topical beta-blockers with or without prostaglandin analogues) controlled intraocular pressure (IOP < 20 mmHg). Subfoveal choroidal blood volume (ChBVol), velocity (ChBVel) and ChBF were determined as the average of three 60 second recordings. In all patients and controls, the PERG and SAP (Humphrey 30-2), following standardized protocols, were also recorded. RESULTS: In patients with EMG, reductions in average ChBVel and ChBF were roughly equal, respectively, by 30% and 33.4% (p < 0.01), when compared to control subjects, so that there was no significant difference in ChBVol between the two groups. Pattern electroretinogram amplitudes were reduced by 46% (p < 0.01) in patients compared to controls. No correlation was found between any of the ChBF parameters and PERG amplitude, or Humphrey 30-2 MD and pattern standard deviation. CONCLUSION: The results suggest a significant alteration of both ChBVel and ChBF in EMG, which does not appear to be associated with the severity of central retinal dysfunction. These findings may contribute to a better understanding of the pathophysiology of early glaucomatous damage in EMG and have implications for the treatment of this pathologic condition.


Assuntos
Corioide/irrigação sanguínea , Glaucoma/fisiopatologia , Retina/fisiopatologia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea/fisiologia , Eletrorretinografia , Feminino , Humanos , Pressão Intraocular/fisiologia , Fluxometria por Laser-Doppler , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional/fisiologia , Acuidade Visual/fisiologia , Testes de Campo Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...